+86 137 5222 7265
+86 188 0644 0456

Home   >  Product Center   >  Gas Alarm System   >  Portable Gas Detector Alarm   >  Model BT-B40BX-E Portable Gas Detector Alarm
>
<

Model BT-B40BX-E Portable Gas Detector Alarm

Detected Gases: Flammable gases and toxic gases such as methane and liquefied petroleum gas (LPG)Main 

Detection Principles: Catalytic Combustion, Electrochemical, Photoionization, Infrared

Sampling Method: Pump Suction

Dimensions: 310mm x 93.6mm x 70mm

Explosion-Proof Mark: Ex d ib IIC T4 Gb

Calibration Modes: Manual Zero Calibration, Standard Gas Calibration

Product Details
Specs & Params
Related Products

Product Description:

Portable Gas Detector & Alarm (Model BT-B40BX-E): It is a pump-suction type gas detection device designed to detect the concentration of a single gas or multiple gases (fewer than 4 types).
Portable Gas Detector & Alarm (Model BT-B40BX) is widely applicable to various places that require flammable/toxic gas concentration detection, such as oil extraction, smelting, chemical industry, municipal administration, sewage treatment, electric power, gas supply, mining, tunnel construction, fire protection, warehousing, papermaking, pharmaceutical industry, and brewing industry.


Product Features:

※ Adopts high-quality gas-sensing elements, featuring high precision, high reliability, excellent gas selectivity and strong anti-interference capability.

※ Utilizes high-speed CPU for processing, enabling automatic fault identification, automatic alarm and automatic protection against high-concentration over-limit.

※ Equipped with a liquid crystal display (LCD) that shows gas concentration and alarm points, with intuitive icon display and simple operation.

※ Uses high-performance rechargeable lithium battery, with charging protection and low-voltage protection functions, and can work continuously for more than 8 hours under normal conditions.

※ Built-in vibration alarm, suitable for use in high-noise environments.

※ Parameter configuration and sensitivity calibration can be performed via mobile phone or computer.


Charging Voltage

DC 5V

Detected Gases

Flammable gases such as methane and liquefied petroleum gas (LPG)

Toxic gases

Detection Principle

Catalytic Combustion

Electrochemical,Photoionization,Infrared

Detection Principle

T90 ≤ 30s

T90 ≤ 60s (for conventional gases)

Operating Time

> 8 hours (when fully charged, under normal detection status)

Sampling Method

Pump Suction

Alarm Method

Audible and Visual Alarm + Vibration

Display Method

LCD

Alarm Sound

70dB ≤ Alarm Sound Signal ≤ 115dB

Operating Temperature

≤ 93% RH (No Condensation)

Operating Humidity

Catalytic Combustion,Photoionization,Infrared: -20°C ~ 55°C
Electrochemical: -25°C ~ 55°C

Explosion-Proof Mark

Ex d ib IIC T4 Gb

Calibration Method

Manual Zero Calibration, Standard Gas Calibration

Dimensions

310mm x 93.6mm x 70mm

Online

Phone

+86 137 5222 7265
+86 188 0644 0456

WeChat

Email

intl.trade@sdbenan.com

Top