Host Power Consumption: ≤10W

Alarm Mode: Audible & Visual Alarm

Capacity: Host: 1 loop, 4 detectors; Power Supply Box: 1 loop, 4 detectors

Signal Transmission Mode: 2-wire Bus (M-Bus, Non-polarized)

Ingress Protection Rating: IP20

Executive Standard:GB 16808-2008

Product Details
Specs & Params
Related Products

Product Description:

Model SSK-ZL-N4 Combustible Gas Alarm Controller is an indoor standalone bus-type controller. It receives, displays and transmits alarm signals from gas detectors, and performs gas leak monitoring, alarm notification and linkage control.

It is applicable to gas leak monitoring scenarios (such as commercial kitchens, boiler rooms, chemical workshops, storage areas and other indoor non-explosion-proof locations). Used as part of gas detection and alarm systems, it provides early warning of leakage risks to prevent safety accidents including explosion and poisoning.


Product Features:

※ Automatic fault detection, accurately indicating fault location and type. 

※ Single-loop 2-wire bus (M-Bus) communication with non-polarized signal design. Equipped with automatic protection, the system features strong anti-interference performance, cost-effective wiring and easy installation. 

※ Built-in data storage to record alarm records, power-on/power-off time and other data; data will not be lost upon power failure. 

※ Automatically identifies detector types and alarm points. Supports monitoring of multiple detector types (%LEL, %VOL, μmol/mol) within one system without manual configuration. 

※ RS485 bus communication interface (standard Modbus/RTU protocol). Supports networking with host control systems for remote monitoring, greatly improving the timeliness and accuracy of monitoring. 

※ Built-in 2 sets of relay contact outputs for linkage control of exhaust fans, solenoid valves and other devices. 

※ LCD display with full Chinese menu operation.

Working Voltage

Host: 

Main power AC220V (85%~110%), 50Hz±1%;

 Backup power: 3.2V/1500mAh (Lithium Iron Phosphate Battery)

Power Supply Box: 

Main power AC220V (85%~110%), 50Hz±1%; 

Backup power: 12V/20Ah (Lithium Iron Phosphate Battery)

Host Power Consumption≤10W
Rated Working Current (Full Load)

Host: Main power 1.1A, Backup power 3.5A 

 Power Supply Box: Main power 1.75A, Backup power 11.1A

Working EnvironmentOperating temperature: -10°C ~ 55°C; Operating humidity: ≤93% RH
CapacityHost: 1 loop, 4 detectors; Power Supply Box: 1 loop, 4 detectors
Alarm ModeAudible & Visual Alarm
Alarm Sound Level65dB ~ 105dB (A-weighted, at 1m in front)
Signal Transmission Mode2-wire Bus (M-Bus, Non-polarized)
Connection Cable≥RWS 2*1.5mm² Twisted Pair
Communication InterfaceRS485 (Modbus/RTU), NB-IoT/4G-CAT1 (Optional)
Control Output Contact Type & Qty2 sets of passive relay normally open/closed contacts; Capacity: 10A/277VAC or 12A/30VDC
Control Output Activation TimeControl output activated within ≤3s after combustible gas alarm signal is sent
Alarm SetpointAutomatically read detector alarm setpoint
IP RatingIP20
Alarm Response TimeAudible & visual alarm issued within 10s after alarm signal input
Fault Alarm Response TimeFault audible & visual alarm issued within 100s after fault signal input
Reset TimeReset completed within 20s; existing alarm status and related information shall remain held after reset, or be re-established within 20s after reset is completed
Timing ErrorDaily timing error ≤6s

Insulation / Leakage Current / 

Dielectric Strength

Insulation resistance ≥100MΩ; Leakage current ≤0.5mA; Dielectric strength 1250V/50Hz/60s
Product DimensionsHost: 211mm*151mm*50.5mm; Power Supply Box:365mm*325mm*115mm