Detected Gas:Methane
Output Interface:1 set of 12V pulse valve actuation output
Display mode:None
Dimensions:80mmx120mmx36mm
Optional Equipment: Emergency Shut-off Valve
Executive Standard:GB 15322.2-2019
Detected Gas:Methane
Output Interface:1 set of 12V pulse valve actuation output
Display mode:None
Dimensions:80mmx120mmx36mm
Optional Equipment: Emergency Shut-off Valve
Executive Standard:GB 15322.2-2019
Product Description:
The Model JT-SSJ05Z03-1-E combustible gas detector is designed in accordance with the national standard GB 15322.2-2019. It can detect the on-site gas concentration in real time and determine whether the gas concentration exceeds the alarm threshold. If the concentration exceeds the threshold, the device will emit audible and visual alarm signals, push alarm information via WeChat, monitoring platform, APP, etc., and simultaneously activate the emergency shut-off valve to cut off the gas supply. It is suitable for leakage monitoring of natural gas pipelines in household interiors.
Product Features:
※ Adopts high-quality gas sensing elements with stable performance and high sensitivity; features excellent anti-poisoning capability and strong anti-interference ability.
※ Equipped with LED life indication.
※ Equipped with a data communication interface.
※ Features a black box function.
※ Concentration and fault alarms are indicated by high-brightness focused LEDs of different colors.
※ High performance, low power consumption, simple operation and easy maintenance.
※ IoT enabled, realizing remote alarm. Easily bound with mobile phones, alarm information is promptly pushed via WeChat.
※ Unique air flow channel and independent gas chamber, which better isolate oil fumes and dust, maintain smooth air flow, and extend service life.
| Rated Voltage | AC 220V±15% |
| Output Interface | 1 set of 12V pulse valve output |
| Measuring Range | 0~16%LEL |
| Alarm Set Value | 8%LEL |
| 检测气体 | 甲烷 |
| Communication Mode (Optional) | NB-IoT/4G-CAT1 |
| Black box function | Yes |
| Operating Temperature | -10°C~55°C |
| Operating Humidity | ≤93%RH(no condensation) |
| Pressure Range | 86kPa ~ 106kPa |
| Material | ABS |
| Installation Method | Wall-mounted |
| Executive Standard | GB 15322.2-2019 |
| Dimensions | 80mm x 120mm x 36mm |
| Optional Equipment | Emergency Shut-Off Valve |