Detected Gas:Methane, Carbon Monoxide, Airborne Particulate Matter, Temperature, Humidity
Operating Voltage:DC3.6V
Dimensions:Φ105.5 mm × 30 mm
Executive Standard:GB 15322.2-2019
Detected Gas:Methane, Carbon Monoxide, Airborne Particulate Matter, Temperature, Humidity
Operating Voltage:DC3.6V
Dimensions:Φ105.5 mm × 30 mm
Executive Standard:GB 15322.2-2019
Product Description:
JTM-SSJ16YG-BAT-E household combustible gas detector is designed in accordance with the national standard GB 15322.2-2019. It can detect the on-site gas concentration in real time and determine whether the gas concentration exceeds the alarm setpoint. When the concentration exceeds the alarm setpoint, the device will send out audible and visual alarm signals and push alarm information via WeChat, platforms, APP and other channels. It is suitable for monitoring methane, carbon monoxide gas and airborne particulate matter in households (such as oil fumes generated by dry burning of cookware), with simultaneous temperature and humidity measurement.
Product Features:
※ The sensor module adopts a composite sensor with high precision, high integration and high reliability.
※ Linear output of concentration value, high sensitivity, stable performance, good anti-poisoning capability and strong anti-interference capability.
※ User-friendly alarm sound adopts easily recognizable fire alarm tone with gradually increasing volume, providing gentle reminder to avoid startling.
※ Manufactured with advanced electronic technology and sophisticated craftsmanship, equipped with high-brightness focused LED indicators of different colors for different working statuses.
※ Lighter weight for easier wall-mounted or adhesive installation.
※ Wireless valve actuation, low power consumption, simple operation and convenient maintenance.
| Operating Voltage | DC 3.0 V |
| Output Interface | One group of 2.4G wireless output |
| Alarm Setpoint | CH₄: 8%LEL, CO: 200×10⁻⁶ (volume fraction), M value: 0.6 dBm |
| Detected Gases | Methane, Carbon Monoxide, Airborne Particulate Matter, Temperature, Humidity |
| Measuring Range | CH₄: 0~16%LEL, CO: (0–1000)×10⁻⁶ (volume fraction) |
| Alarm Mode | Audible and visual alarm |
| Sampling Method | Natural Diffusion |
| Communication Mode | 4G-CAT1 |
| Operating Temperature | -10°C~55°C |
| Operating Humidity | ≤93%RH(No Condensation) |
| Dimensions | Φ105.5 mm × 30 mm |
| Material | ABS |
| Mounting Method | Wall-mounted / Ceiling-mounted |
| Executive Standard | GB 15322.2-2019 |