Detected Gas:Methane
Alarm Set Value:10%LEL
Dimensions:95mm×95mm×38mm
Installation Method:Wall-mounted, Ceiling-mounted
Executive Standard:GB 15322.2-2019
Detected Gas:Methane
Alarm Set Value:10%LEL
Dimensions:95mm×95mm×38mm
Installation Method:Wall-mounted, Ceiling-mounted
Executive Standard:GB 15322.2-2019
Product Description:
The JT-SSJ10W16-E type flammable gas detector is designed in accordance with GB 15322.2-2019. It can detect the on-site gas concentration in real time and determine whether the gas concentration exceeds the alarm value. If the alarm value is exceeded, the device will issue an audible and visual alarm signal, push alarm information via WeChat, platforms, APPs, etc., and can be linked with an emergency shut-off valve to cut off the gas supply. It is suitable for leakage monitoring of indoor natural gas pipelines in households.
Product Features:
※ Adopts advanced optoelectronic integration technology to achieve high-precision, high-integration, high-reliability miniaturized integrated packaging.
※ Intrinsically zero-drift, no need for external temperature compensation, and linear output of concentration values.
※ Tolerance: The optoelectronic chip adopts hermetic packaging, which is not affected by external environmental interference.
※ Safe and stable: No chemical reactions occur during the detection process, and no excess gases or substances are generated.
※ Calibration-free: The sensor is self-adaptive and performs self-calibration through hardware and software algorithms.
※ Stable performance, high sensitivity, excellent anti-toxicity, and strong anti-interference capability.
※ The unique air flow channel and independent air chamber can better isolate oil fumes and dust, maintain smooth air flow, and extend the service life.
| Rated Voltage | AC 220V±15% |
| Output Interface | 1 set of 12V pulse output / 1 set of 2.4G output (optional) |
| Alarm Set Value | 10%LEL |
| Detected Gas | Methane |
| Measuring Range | 0~100%LEL |
| Error | ±3%LEL |
| Alarm Method | Audible and Visual Alarm |
| Sampling Method | Free Diffusion Type |
| Communication Method (Optional) | 4G-CAT1 |
| Operating Temperature | -10°C~55°C |
| Operating Humidity | ≤93%RH (No Condensation) |
| Dimensions | 95mm×95mm×38mm |
| Material | ABS |
| Installation Method | Wall-mounted, Ceiling-mounted |
| Executive Standard | GB 15322.2-2019 |